ver : b_8 update : 2015.11.16 ac-dc power module anc50 series 50 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. ( single output ) anc50-5s ANC50-12S anc50-15s anc50-24s anc50-48s max output wattage (w) 40w 50w 50w 50w 50w voltage 90-264 vac or 120-370 vdc frequency (hz) 47-63 hz current (full load) 1000 ma max. (115 vac) / 600 ma max. (230 vac) inrush current (<2ms) 40 a max. (115 vac) / 60 a max. (230 vac) leakage current 0.25 ma max. input external fuse (recommend) 3.15 a slow blow type voltage (v.dc.) 5v 12v 15v 24v 48v voltage accuracy 2% current (ma) max 8000 4167 3333 2083 1040 line regulation (ll-hl) (typ.) 1% load regulation (0-100%) (typ.) 1% minimum load 0% maximum capacitive load 10000 uf 3500 uf 3000 uf 2200 uf 330uf ripple & noise 120mv 120mv 150mv 240mv 480mv efficiency (at 230 vac) 86% 90% 87% 88% 89% hold-up time 10 ms min. output switching frequency (typ.) ( at 230 vac ) 65 khz over power protection hicc up technique, auto-recovery over voltage protection zener diode clamp protection short circuit protection hiccup mode, indefinite (automatic recovery) input-output (v.ac) 3000v input-fg (v.ac) 1500v isolation output-fg (v.ac) 500v operating temperature -40c?+70c (with derating) storage temperature -40c?+85c temperature coefficient 0.02%/c humidity 95% rh environment mtbf >300,000 h @ 25c (mil-hdbk-217f) dimension (l x w x h) 2.91 x 2.13 x 0.86 inches ( 74.1 x 54.1 x 21.8 mm ) tolerance ? 0.5 mm case material plastic resin (flammability to ul 94v-0) weight 166 g physical cooling method free air convection key features ? switching power module for pcb mountable ? fully encapsulated plastic case ? regulated output and low ripple and noise ? small size as anc 15watt with 50watt higher power ? ce, ul approval ? 3-year product warranty
ver : b_8 update : 2015.11.16 ac-dc power module anc50 series 50 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- derating electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. ( single output ) anc50-5s ANC50-12S anc50-15s anc50-24s anc50-48s safety agency approvals ce, ul/cul emi (conducted & radiated emission) en 55022 ems (noise immunity) en 55024 esd en61000-4-2 air 8kv , contact 4kv (a) radiated immunity en61000-4-3 3v/m (a) fast transient en61000-4-4 1kv (a) surge en61000-4-5 2kv (a) conducted immunity en61000-4-6 3vrms (a) pfmf en61000-4-8 1a/m (a) emc dips en61000-4-11 30% 500ms (a) note 1. ripple & noise are measured at 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor. 2. it's recommended to add varistor 14s471k at l / n input side in parallel. 3. please refer to our pdf file "ac-dc applic ation" on our website: www.archcorp.com.tw mechanical dimension ( top view ) block diagram pin# single 1 ac in (n) 2 ac in (l) 3 -dc out 4 +dc out
|